Plate 18: Compartment ventilating and supply systems (emergency ventilating)

 

     

   
PLAN 18 - RAUMLUFTUNGSANLAGE RAUMNOTLUFTEINRICHTUNG
Compartment Ventilating and Supply Systems (Emergency Ventilating)
     
 
a ZULUFT . . . zB TURM
  Air supply . . . for example, to conning tower
   
a1 WARMZULUFT SEHROHR
  Warm air supply to periscope
   
a2 NOTZULUFT TURM
  Emergency air supply to conning tower
   
a3 BORDVENTIL NOTZULUFT ZENTRALE und TRUM
  Hull valve, emergency air supply to control room and conning tower
   
a4 BORDABSPERRUNG NOTZULUFTHAHN
  Hull valve, emergency air supply
   
b ABLUFT . . . zB HORCHRAUM
  Exhaust air . . . for example, listening room
   
b1 NATÜRLICHE ABLUFT . . . zB BATTERIE 1
  Emergency air exhaust . . . for example, battery compartment 1
   
b2 NOTABLUFT TRUM
  Emergency air exhaust . . . for example, conning tower
   
b3 BORDVENTIL NOTABLUFT ZENTRALE und TURM
  Hull valve, emergency air exhaust, control room and conning tower
   
b4 BORDABSPERRUNG NOTLUFTRAHN . . . zB HECKTORPEDO un ELEK. MASCH. RAUM
  Hull valve emergency air exhaust . . . for example after torpedo and electric motor room
   
b5 BORDABSPERRUNG MOTLUFTRAHN . . . zB TRUM
  Hull valve emergency air exhaust . . . for example to conning tower
   
c ZULUFTFUSZVENTIL
  Ventilation supply, hull valve
   
c1 ABLUFTFUSZVENTIL
  Ventilation exhaust, hull valve
   
d ZULUFTKOPPVENTIL
  Ventilation supply, outboard valve
   
d1 ABLUFTKOPPVENTIL
  Ventilation exhaust, outboard valve
   
d2 TURMLUFTKOPPVENTIL
  Air connection to bridge
e REGELVENTIL LUFTERNEUERUNSGERÄT
  Regulating valve, air conditioners
   
f ANSCHLUSZ ABSAUGEN ETO
  Suction connection to Eto
   
f1 ZULUFTANSCHLUSZ TURM
  Air supply to conning tower
   
f2 ABLUFTANSCHLUSZ . . . zB HORCHRAUM
  Ventilating air exhaust connection . . . for example, listening room
   
f3 NOTZULUFTANSCHLUSZ ZENTRALE und TURM
  Emergency air supply connection to control room and conning tower
   
f4 NOTABLUFTANSCHLUSZ ZENTRALE und TURM
  Emergency air exhaust connection to control room and conning tower
   
g ZULUFTSTRANG . . . zB BUGTORPEDORAUM
  Bulkhead stop valves, ventilation supply line . . . for example, to forward torpedo room
   
g1 ABLUFTSTRANG . . . zB HINTEN DISELMOTORENRAUM
  Bulkhead stop valves, ventilation exhaust line . . . for example to after end Diesel engine room
   
h VERBINDUNG RAUMLUFTER
  Cross-connection valve, compartment ventilation systems; i.e., connects port and starboard systems
   
i RAUMZULUFTWÄHLER
  Compartment air exhaust selector
   
k RAUMABLUFTSCHALTER
  Compartment air exhaust selector
   
k1 NOTZULUFTSCHALTER
  Emergency ventilating air supply control
   
k2 NOTABLUFTSCHALTER
  Emergency ventilating air exhaust control
   
k3 SAUERSTOFFSCHALTER . . . zB DISELMOTORAUM
  Oxygen supply control . . . for example, Diesel engine room
   
l ABSAUGEN . . . zB KÜCHE
  Ventilating blower fan . . . for example, galley
   
m ENTWÄSSERN . . . zB ZULUFTFUSSVENTIL
  Drain valve . . . for example, ventilating air supply foot valve